Category Archives: Logic Analyzers

buy logic analyzers today or rent or lease them.

16756A – Agilent / HP Logic Analyzers

16756A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       The Agilent 16756A state and timing analysis module with 64M memory, delivers the performance and capabilities you need to debug and validate digital systems using new high-speed system interconnects and buses. The innovative eye scan mode in the 16756A enables you to examine eye diagrams on multiple circuit modes simultaneously, for a rapid, comprehensive view of signal integrity. Another feature, eye finder automatically adjusts the position of the data valid window on every channel independently, ensuring the most reliable data capture on high-speed buses and interconnects.

Accurate & Reliable Measurements Begin at the Probe Tip!

•Eye scan feature saves you time and gives you confidence by measuring eye diagrams on hundreds of channels simultaneously without having to move probes
•4 GHz timing zoom, (simultaneous timing analysis on all channels), with 64 K memory for unprecedented time coverage of high-resolution timing measurements
•Eye finder feature automatically adjusts data valid window position on each channel with ps resolution

Specifications
Max. Channels Number68

Max. State Speed600.0MHz

Max. Timing Speed1GHz

More Details
State and timing module

16755A – Agilent / HP Logic Analyzers

16755A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       The Agilent 16755A state and timing analysis module with 16M memory, delivers the performance and capabilities you need to debug and validate digital systems using today’s new high-speed system interconnects. The innovative “eye scan” mode in the 16755A enables you to examine eye diagrams and buses, on multiple circuit nodes simultaneously, for a rapid, comprehensive view of signal integrity. Another feature, “eye finder” automatically adjusts the position of the data valid window on every channel independently, ensuring the most reliable data capture on high-speed interconnects and buses. Features: “Eye scan” feature saves you time and gives you confidence by measuring eye diagrams on hundreds of channels simultaneously without having to move probes 4 GHz “timing zoom”, (simultaneous timing analysis on all channels), with 64 K memory for unprecedented time coverage of high-resolution timing measurements “Eye finder” feature automatically adjusts data valid window position on each channel with ps resolution

Specifications
Max. Channels Number68

Max. State Speed600.0MHz

Max. Timing Speed4GHz

More Details
Logic analyzer Timing and State Module

16754A – Agilent / HP Logic Analyzers

16754A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       The Agilent 16754A state and timing analysis module with 4M memory, delivers the performance and capabilities you need to debug and validate digital systems using the new high-speed system interconnects of today. The innovative eye scan mode in the 16754A enables you to examine eye diagrams on multiple circuit nodes simultaneously, for a rapid, comprehensive view of signal integrity. Another feature, eye finder automatically adjusts the position of the data valid window on every channel independently, ensuring the most reliable data capture on high-speed interconnect and buses.

•Eye scan feature saves you time and gives you confidence by measuring eye diagrams on hundreds of channels simultaneously without having to move probes
•4 GHz timing zoom, (simultaneous timing analysis on all channels), with 64 K memory for unprecedented time coverage of high-resolution timing measurements
•Eye finder feature automatically adjusts data valid window position on each channel with ps resolution

Specifications
Max. Channels Number68

Max. State Speed600.0MHz

Max. Timing Speed1GHz

More Details
State and timing module

16753A – Agilent / HP Logic Analyzers

16753A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                               The Agilent 16753A state and timing analysis module delivers the performance and capabilities you need to debug and validate digital systems using the new high-speed system interconnects and buses of today. The innovative “eye scan” mode in the 16753A enables you to examine eye diagrams on multiple circuit nodes simultaneously, for a rapid, comprehensive view of signal integrity. Another feature, “eye finder,” automatically adjusts the position of the data valid window on every channel independently, ensuring the most reliable data capture on high-speed interconnects and buses.

Specifications
Max. Channels Number68

Max. State Speed600.0MHz

Max. Timing Speed1GHz

More Details
State and timing module

16752B – Agilent / HP Logic Analyzers

16752B – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                               The Agilent 16752B logic analysis module offers industry-leading memory depth and performance for your future digital designs. The 16752B can be combined with 16752A modules in multi-module sets.

•32M of acquisition memory is available to help link a symptom of a problem with the cause
•Innovative hardware in the 16752B improves the system performance
400 MHz state speed
•2 GHz Timing Zoom provides high-speed state and timing analysis simultaneously through a single probe connection to the device under test
•VisiTrigger™ technology combines new trigger functionality with a user interface that is easy to use and understand
•68 to 340 channels of data capture on the same time base and trigger
•Eye Finder automatically adjusts setup and hold for highest confidence in measurements on high-speed buses

Specifications
Max. Channels Number68

Max. State Speed400.0MHz

Max. Timing Speed800MHz

More Details
State and timing module