16911A – Agilent / HP Logic Analyzers 68 (Max. Channels Number) •68 channels
•4 GHz (250 ps) timing zoom with 64K memory depth
•500 MHz / 1 GHz (full / half-channel) conventional timing with deep memory
•500 MHz transitional timing
•Selectable memory depths of 256K, 1M, 4M, 16M, or 32M.
•Supports clock rates up to 250 MHz or 450 MHz
•Supports data rates up to 250 Mb/s or 500 Mb/s
•Comprehensive single-ended threshold support (-5V to 5V in 10 mV increments)
•Eyefinder automatically adjusts setup and hold for accurate measurements on high-speed buses
•Memory Depth and State Speed Upgrade Options:
■Option 256: Acquisition memory depth of 256K. Included in base configuration of module at purchase
■Option 001: Increase acquisition memory depth to 1M at the time of module purchase
■Option 004: Increase acquisition memory depth to 4M at the time of module purchase
■Option 016: Increase acquisition memory depth to 16M at the time of module purchase
■Optioin 032: Increase acquisition memory depth to 32M at the time of module purchase
■Option 250: Maximum state speed of 250 MHz. Included in base configuration of module at purchase
■Option 500: Increase maximum state speed to 450 MHz at the time of module purchase
Specifications
Max. Channels Number68
Max. State Speed450.0MHz
Max. Timing Speed4GHz
More Details
68-Channel 4 GHz Timing/250 MHz State Logic Analysis Module
1682AD – Agilent / HP Logic Analyzers 68 (Max. Channels Number) The award-winning 1680 Series standalone and 1690 Series PC-hosted logic analyzers simplify complex logic analysis measurements in a remarkably intuitive, easy-to-navigate Windows®-based environment.
•800 MHz timing with 4 M deep memory enables you to find the root cause of a problem that is widely separated from the symptom in time.
•200 MHz state acquisition provides you performance and headroom for synchronous system measurements.
•Simple and Quick triggers let you define triggers in the context of the signals you”’re viewing. Use pull-down menus within data displays to define trigger events as edges, patterns and glitches (Simple trigger) or draw a box around a suspect event in the display to see if it reoccurs (Quick trigger).
•Advanced trigger lets you use drag-and-drop graphical icons as building blocks to customize complex trigger scenarios to find the most elusive problems.
•Time correlated measurements between an external oscilloscope and the logic analyzer help you determine how the analog quality of a signal impacts the digital operation of your device.
•Offline analysis allows you to analyze previously captured data on a Windows PC leaving your logic analyzer free to capture additional data.
•12.1-inch built-in color flat panel display allows you to see more data and gain insight quickly.
•68 channel standalone logic analyzer.
1682A – Agilent / HP Logic Analyzers 68 (Max. Channels Number) 800 MHz timing with 1 M deep memory enables you to find the root cause of a problem that is widely separated from the symptom in time. 200 MHz state acquisition provides you performance and headroom for synchronous system measurements. Simple and Quick triggers let you define triggers in the context of the signals you”’re viewing. Use pull-down menus within data displays to define trigger events as edges, patterns and glitches (Simple trigger) or draw a box around a suspect event in the display to see if it reoccurs (Quick trigger). Advanced trigger lets you use drag-and-drop graphical icons as building blocks to customize complex trigger scenarios to find the most elusive problems. Time correlated measurements between an external oscilloscope and the logic analyzer help you determine how the analog quality of a signal impacts the digital operation of your device. Offline analysis allows you to analyze previously captured data on a Windows PC leaving your logic analyzer free to capture additional data. 12.1-inch built-in color flat panel display allows you to see more data and gain insight quickly. 68 channel standalone logic analyzer.
16822A – Agilent / HP Logic Analyzers 68 (Max. Channels Number) •15 inch color display, available touch screen – view relationships between large numbers of signals and buses to identify a problem sooner
•Pattern generator – get stimulus and response in a single instrument with the only portable logic analyzer to include a built-in pattern generator. Maximum clock rate: 300 MHz, maximum memory depth: 16 M Vectors
•32 M deep memory – capture symptom and root cause that are widely separated in time
•Up to 204 channels – choose from eight models to match your specific measurement needs
•Upgradeable memory depth and state speed – purchase the capability you need now, then upgrade as your needs evolve
Specifications
Max. Channels Number68
Max. State Speed450.0MHz
Max. Timing Speed4GHz
More Details
Portable Logic Analyzer with 48-ch Pattern Generator
16802A – Agilent / HP Logic Analyzers 68 (Max. Channels Number) The Agilent 16802A 68-channel portable logic analyzer provides 1 GHz timing, 250 MHz state, 1 M deep memory, and 250 ps resolution (4 GHz)/ 64K deep timing zoom. Upgradeable logic analyzer memory depth allows you to purchase the capability you need now and upgrade as your needs evolve. The fixed configuration with 15″ display (touch screen available) delivers the performance you need along with seamless scope integration and an intuitive interface to help you quickly overcome the toughest digital debug challenges – all at an affordable price.
•4 GHz timing/450 MHz state analysis
•68 channels
•15-inch color display, a viewing area more than twice as large as other logic analyzers in its class, allows you to see more data. Viewing relationships between large numbers of signals and buses helps you identify a problem sooner
•Up to 32 M deep memory and 450 MHz state speed allows you to capture the most elusive problems. Extend the life of your equipment by easily upgrading memory depth as your needs evolve
•View Scope quickly lets you validate signal integrity and timing relationships between analog and digital domains by seamlessly integrating your scope and logic analyzer waveforms into a single display. Simple LAN and BNC connection