16998A – Agilent / HP Logic Analyzers

16998A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                      The 16998A High-performance FPGA Analyzer provides a convenient, single model number for purchasing a high-performance FPGA debug and validation system. The system includes support for both Xilinx and Altera FPGAs. The analyzer comes with 4 M of acquisition memory, essential for capturing enough system activity to get to the root cause of complex problems.

Expandability is the key to the analyzer´s long-term value. As your needs evolve you can customize this system with innovative probing, high-performance measurement modules, and post-processing analysis tools.

•Correlate internal FPGA activity with external events in the surrounding system
•Access up to 128 internal signals per each FPGA pin dedicated to debug
•Acquire single-ended and differential signals, threshold is adjustable from -3V to 5V (10 mV increments)
•Free 4 M acquisition memory and FPGA Dynamic Probes for Xilinx and Altera
•State clock rates up to 667 MHz
•Data rates: up to 1066 Mb/s (Dual Sample), up to 667 Mb/s (Double Data Rate – DDR)
•4 GHz (250 ps) timing zoom with 64 K memory
•1.2 GHz / 600 MHz (half / full-channel) conventional timing with deep memory 600 MHz transitional timing
•Xilinx and Altera FPGA Compatibility
•Xilinx devices: Virtex-5, Virtex-4, Virtex-II Pro, Virtex-II, and Spartan-3/3E/3A; Requires Xilinx ChipScope Pro or Embedded Development Kit (EDK)
•Altera devices: Stratix series, Cyclone series, MAX series, APEX series, and Excaliber series; Requires Altera Quartus II Logic Analyzer Interface
•16901A 2-slot modular logic analyzer with 15-inch (38.1 cm) color touch screen display
•68-channel 16950B logic analyzer module with 4 M acquisition memory – Additional slot available for additional measurement capability
•B4655A FPGA Dynamic Probe for Xilinx, B4656A FPGA Dynamic Probe for Altera
•Compatible with 90-pin logic analyzer probes

Specifications
Max. Channels Number68

Max. State Speed667.0MHz

Max. Timing Speed4GHz

More Details
High-performance FPGA Analyzer

16951B – Agilent / HP Logic Analyzers

16951B – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                      The 16951B logic analyzer module offers the deepest memory depth in the industry, across all channels. Deep memory allows you to maximize the time covered by your measurement. In addition, the module offers the highest performance for your most demanding digital debug applications.

•256 M memory depth (extend the time covered by your measurement window)
•4 GHz (250 ps) timing zoom with 64 K memory depth
•State clock rates up to 667 MHz
•Data rates up to 1066 Mb/s
•600 MHz / 1.2 GHz (full / half-channel) conventional timing with deep memory
•600 MHz transitional timing
•68 channels per module (combine modules for higher-channel counts)
•Comprehensive single-ended and differential threshold support
•Automated threshold/sample position for accurate measurements on high-speed buses
•Simultaneous eye diagrams on all channels identifies problem signals quickly

Specifications
Max. Channels Number68

Max. State Speed667.0MHz

Max. Timing Speed4GHz

More Details
Logic Analyzer Module

16950B – Agilent / HP Logic Analyzers

16950B – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       The 16950B logic analyzer module offers the highest performance for your most demanding digital debug applications.

•4 GHz (250 ps) timing zoom with 64 K memory depth
•State clock rates up to 667 MHz
•Data rates up to 1066 Mb/s
•600 MHz / 1.2 GHz (full / half-channel) conventional timing with deep memory
•600 MHz transitional timing
•Selectable memory depths: 1 M, 4 M, 16 M, 32 M, or 64 M
•68 channels per module (combine modules for higher-channel counts)
•Comprehensive single-ended and differential threshold support
•Automated threshold/sample position for accurate measurements on high-speed buses
•Simultaneous eye diagrams on all channels identifies problem signals quickly

Specifications
Max. Channels Number68

Max. State Speed667.0MHz

Max. Timing Speed4GHz

More Details
Timing and State Logic Analyzer Module

16950A – Agilent / HP Logic Analyzers

16950A – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       •68 channels
•4 GHz (250 ps) timing zoom with 64K memory depth
•600 MHz / 1.2 GHz (full / half-channel) conventional timing with deep memory
•600 MHz transitional timing
•Selectable memory depths of 256K, 1M, 4M, 16M, 32M, or 64M
•Supports clock rates up to 600 MHz
•Supports data rates up to 800 Mb/s
•Comprehensive single-ended threshold support (-3V to 5V in 10 mV increments)
•Eyefinder automatically adjusts setup and hold for accurate measurements on high-speed buses
•Eye scan mode provides rapid multi-channel signal integrity characterization
•Memory Depth Upgrade Options:
■Option 256: Acquisition memory depth of 256K. Included in base configuration of module at purchase
■Option 001: Increase acquisition memory depth to 1M at the time of module purchase
■Option 004: Increase acquisition memory depth to 4M at the time of module purchase
■Option 016: Increase acquisition memory depth to 16M at the time of module purchase
■Optioin 032: Increase acquisition memory depth to 32M at the time of module purchase
■Optioin 064: Increase acquisition memory depth to 64M at the time of module purchase

Specifications
Max. Channels Number68

Max. State Speed600.0MHz

Max. Timing Speed4GHz

More Details
68 Channel 4 GHz Timing/600 MHz State Logic Analysis Module

1692AD – Agilent / HP Logic Analyzers

1692AD – Agilent / HP Logic Analyzers
68 (Max. Channels Number)                                                                                                                                                                                       800 MHz timing with 4 M deep memory enables you to find the root cause of a problem that is widely separated from the symptom in time. 200 MHz state acquisition provides you performance and headroom for synchronous system measurements. Simple and Quick triggers let you define triggers you need in the context of signals you are viewing. Use pull-down menus within data displays to define trigger events as edges, patterns and glitches (Simple trigger) or draw a box around a suspect event in the display to see if it reoccurs (Quick trigger). Advanced trigger lets you use drag-and-drop graphical icons as building blocks to customize complex trigger scenarios to find the most elusive problems. Time correlated measurements between an external oscilloscope and the logic analyzer help you determine how the analog quality of a signal impacts the digital operation of your device. Offline analysis allows you to analyze previously captured data on a Windows PC leaving your logic analyzer free to capture additional data. PC-hosted version provides small footprint, saving valuable workspace. View your captured traces at the display size and resolution of your PC. An IEEE 1394 port provides direct connection to a 500 MHz minimum Intel Celeron or AMD K-6 II (or equivalent) PC running Windows 2000 Professional. 68 channel PC hosted logic analyzer

Specifications
Max. Channels Number68

Max. State Speed200.0MHz

Max. Timing Speed800MHz

More Details