<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Premium Test Equipment &#187; Accessories</title>
	<atom:link href="https://www.premiumtestequipment.com/category/accessories/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.premiumtestequipment.com</link>
	<description>Sell, Rent, Lease &#38; Buy Electronic Test Equipment</description>
	<lastBuildDate>Wed, 22 Feb 2017 03:48:05 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.0.33</generator>
	<item>
		<title>1134A Agilent InfiniiMax 7 GHz Probe</title>
		<link>https://www.premiumtestequipment.com/1134a-agilent-infiniimax-7-ghz-probe/</link>
		<comments>https://www.premiumtestequipment.com/1134a-agilent-infiniimax-7-ghz-probe/#comments</comments>
		<pubDate>Mon, 17 Feb 2014 04:11:31 +0000</pubDate>
		<dc:creator><![CDATA[Jeff Newman]]></dc:creator>
				<category><![CDATA[AGILENT]]></category>
		<category><![CDATA[Probes]]></category>

		<guid isPermaLink="false">http://www.premiumtestequipment.com/?p=15685</guid>
		<description><![CDATA[1134A Agilent InfiniiMax 7 GHz Probe 7 GHz Key Features &#38; Specifications Bandwidth: •Bandwidth: 7 GHz Range: •Dynamic Range: +/- 2.5V •DC Offset Range: +/- 12V •Maximum Voltage: +/- 30V Input Impedance: •Differential Input R: 50 kOhm •Differential Input C: 0.27-0.34 pF •Single Ended Input R: 25 kOhm •Single Ended Input C: 0.44-0.67 pF Connectivity: [&#8230;]]]></description>
		<wfw:commentRss>https://www.premiumtestequipment.com/1134a-agilent-infiniimax-7-ghz-probe/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>85024A Agilent High-Frequency Probe, 300 kHz to 3 GHz</title>
		<link>https://www.premiumtestequipment.com/85024a-agilent-high-frequency-probe-300-khz-to-3-ghz/</link>
		<comments>https://www.premiumtestequipment.com/85024a-agilent-high-frequency-probe-300-khz-to-3-ghz/#comments</comments>
		<pubDate>Mon, 17 Feb 2014 04:09:29 +0000</pubDate>
		<dc:creator><![CDATA[Jeff Newman]]></dc:creator>
				<category><![CDATA[AGILENT]]></category>
		<category><![CDATA[Probes]]></category>

		<guid isPermaLink="false">http://www.premiumtestequipment.com/?p=15683</guid>
		<description><![CDATA[85024A Agilent High-Frequency Probe 300 kHz to 3 GHz Key Features &#38; Specifications •Easy to perform in-circuit measurements •Excellent frequency response and unity gain •High probe sensitivity •Low distortion levels Description The Agilent 85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of [&#8230;]]]></description>
		<wfw:commentRss>https://www.premiumtestequipment.com/85024a-agilent-high-frequency-probe-300-khz-to-3-ghz/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>U1818B Agilent Active Differential Probe, 100 kHz to 12 GHz</title>
		<link>https://www.premiumtestequipment.com/u1818b-agilent-active-differential-probe-100-khz-to-12-ghz/</link>
		<comments>https://www.premiumtestequipment.com/u1818b-agilent-active-differential-probe-100-khz-to-12-ghz/#comments</comments>
		<pubDate>Mon, 17 Feb 2014 04:05:09 +0000</pubDate>
		<dc:creator><![CDATA[Jeff Newman]]></dc:creator>
				<category><![CDATA[AGILENT]]></category>
		<category><![CDATA[Probes]]></category>

		<guid isPermaLink="false">http://www.premiumtestequipment.com/?p=15680</guid>
		<description><![CDATA[U1818B Agilent Active Differential Probe 100 kHz to 12 GHz Key Features &#38; Specifications •Broad bandwidth with flat frequency response, +/- 1.5 dB, ensures excellent measurement accuracy and helps you achieve the best product specifications •Low noise floor, less than -130 dBm/Hz at 10 MHz to 12 GHz, which allows measurements to be made at [&#8230;]]]></description>
		<wfw:commentRss>https://www.premiumtestequipment.com/u1818b-agilent-active-differential-probe-100-khz-to-12-ghz/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>41800A Agilent Active Probe, 5 Hz to 500 MHz</title>
		<link>https://www.premiumtestequipment.com/41800a-agilent-active-probe-5-hz-to-500-mhz/</link>
		<comments>https://www.premiumtestequipment.com/41800a-agilent-active-probe-5-hz-to-500-mhz/#comments</comments>
		<pubDate>Mon, 17 Feb 2014 04:02:27 +0000</pubDate>
		<dc:creator><![CDATA[Jeff Newman]]></dc:creator>
				<category><![CDATA[AGILENT]]></category>
		<category><![CDATA[Probes]]></category>

		<guid isPermaLink="false">http://www.premiumtestequipment.com/?p=15678</guid>
		<description><![CDATA[41800A Agilent Active Probe 5 Hz to 500 MHz Description The Agilent 41800A Active Probe provides high input impedance from 5 Hz to 500 MHz. The Agilent 41800A is a valuable tool when used with a network and spectrum analyzer for circuit signal analysis.]]></description>
		<wfw:commentRss>https://www.premiumtestequipment.com/41800a-agilent-active-probe-5-hz-to-500-mhz/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>U1818A Agilent Active Differential Probe, 100 kHz to 7 GHz</title>
		<link>https://www.premiumtestequipment.com/u1818a-agilent-active-differential-probe-100-khz-to-7-ghz/</link>
		<comments>https://www.premiumtestequipment.com/u1818a-agilent-active-differential-probe-100-khz-to-7-ghz/#comments</comments>
		<pubDate>Mon, 17 Feb 2014 03:58:59 +0000</pubDate>
		<dc:creator><![CDATA[Jeff Newman]]></dc:creator>
				<category><![CDATA[AGILENT]]></category>
		<category><![CDATA[Probes]]></category>

		<guid isPermaLink="false">http://www.premiumtestequipment.com/?p=15676</guid>
		<description><![CDATA[U1818A Agilent Active Differential Probe 100 kHz to 7 GHz Key Features &#38; Specifications •Broad bandwidth with flat frequency response, +/- 1.5 dB, ensures excellent measurement accuracy and helps you achieve the best product specifications •Low noise floor, less than -130 dBm/Hz at 10 MHz to 7 GHz, which allows measurements to be made at [&#8230;]]]></description>
		<wfw:commentRss>https://www.premiumtestequipment.com/u1818a-agilent-active-differential-probe-100-khz-to-7-ghz/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
